https://www.simufly.com/cgi-bin/yabb2/YaBB.pl Delco Carousel IV-A INS For Microsoft Flight Simulator >> Delco Carousel IV-A INS For Microsoft Flight Simulator >> 06-56 https://www.simufly.com/cgi-bin/yabb2/YaBB.pl?num=1535703997 Message started by stevejames on Aug 31st, 2018, 9:26am |
Title: 06-56 Post by stevejames on Aug 31st, 2018, 9:26am Hi In an a/c with 3x units, I had one CDU with a totally wrong POS in flight, I don't know why. I waited for a VOR and did a manual update which worked and then did a dual auto update with an on-route and off route VOR. I got the PI down to 1 on all 3 CDU's but still the 06-56 error would not clear, anyone any idea why please ? Best Steve |
Title: Re: 06-56 Post by Marco Ravanello on Sep 4th, 2018, 2:35pm Steve, please check ActionAndMalfunctionCodes.pdf document to understand what 06-56 means and how to handle the condition. Marco |
Title: Re: 06-56 Post by stevejames on Sep 6th, 2018, 2:32pm Hi Marco Thanks for your reply. I have read the manual, my understanding is the message can be cleared once the INS POS is back correct, which if my PI is 1 I would have thought was good enough to clear the error. Best Steve |
Title: Re: 06-56 Post by Marco Ravanello on Sep 6th, 2018, 3:12pm Steve, I'd have to look at the source code to understand if what you experienced is due to one of the many "simulated features" the INS could randomly auto-generate. If that is the case then there is nothing you could do to clear it. |